Universidad de Granada Digibug
 

Repositorio Institucional de la Universidad de Granada >
1.-Investigación >
Departamentos, Grupos de Investigación e Institutos >
Departamento de Teoría de la Señal, Telemática y Comunicaciones >
DTSTC - Artículos >

Please use this identifier to cite or link to this item: http://hdl.handle.net/10481/36991

Title: Comparison between Different Intensity Normalization Methods in 123I-Ioflupane Imaging for the Automatic Detection of Parkinsonism
Authors: Brahim, A.
Ramírez Pérez de Inestrosa, Javier
Górriz Sáez, Juan Manuel
Khedher, Laila
Salas-González, Diego
Issue Date: 2015
Abstract: Intensity normalization is an important pre-processing step in the study and analysis of DaTSCAN SPECT imaging. As most automatic supervised image segmentation and classification methods base their assumptions regarding the intensity distributions on a standardized intensity range, intensity normalization takes on a very significant role. In this work, a comparison between different novel intensity normalization methods is presented. These proposed methodologies are based on Gaussian Mixture Model (GMM) image filtering and mean-squared error (MSE) optimization. The GMM-based image filtering method is achieved according to a probability threshold that removes the clusters whose likelihood are negligible in the non-specific regions. The MSE optimization method consists of a linear transformation that is obtained by minimizing the MSE in the non-specific region between the intensity normalized image and the template. The proposed intensity normalization methods are compared to: i) a standard approach based on the specific-to-non-specific binding ratio that is widely used, and ii) a linear approach based on the α-stable distribution. This comparison is performed on a DaTSCAN image database comprising analysis and classification stages for the development of a computer aided diagnosis (CAD) system for Parkinsonian syndrome (PS) detection. In addition, these proposed methods correct spatially varying artifacts that modulate the intensity of the images. Finally, using the leave-one-out cross-validation technique over these two approaches, the system achieves results up to a 92.91% of accuracy, 94.64% of sensitivity and 92.65 % of specificity, outperforming previous approaches based on a standard and a linear approach, which are used as a reference. The use of advanced intensity normalization techniques, such as the GMM-based image filtering and the MSE optimization improves the diagnosis of PS.
Sponsorship: This work was partly supported by the MICINN under the TEC2012-34306 project and the Consejería de Innovación, Ciencia y Empresa (Junta de Andalucía, Spain) under the Excellence Project P11-TIC-7103. This work has also been supported by a Marie Curie Intra-European Fellowship from the 7th Framework Programme FP7-PEOPLE-2013-IEF (Project: 624453 ALPHA-BRAIN-IMAGING) and ERASMUS MUNDUS AL-IDRISI I.
Publisher: Public Library of Science (Plos)
Keywords: Imaging techniques
Neostriatum
Single photon emissions computed tomography
Neuroimaging
Optimization
Parkinson disease
Principal component analysis
Image analysis
URI: http://hdl.handle.net/10481/36991
ISSN: 1932-6203
Rights : Creative Commons Attribution-NonCommercial-NoDerivs 3.0 License
Citation: Brahim, A.; et al. Comparison between Different Intensity Normalization Methods in 123I-Ioflupane Imaging for the Automatic Detection of Parkinsonism. Plos One, 10(6): e0130274 (2015). [http://hdl.handle.net/10481/36991]
Appears in Collections:OpenAIRE (Open Access Infrastructure for Research in Europe)
DTSTC - Artículos

Files in This Item:

File Description SizeFormat
Brahim_Parkinson.pdf3.1 MBAdobe PDFView/Open
Recommend this item

This item is licensed under a Creative Commons License
Creative Commons

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! OpenAire compliant DSpace Software Copyright © 2002-2007 MIT and Hewlett-Packard - Feedback

© Universidad de Granada