Universidad de Granada Digibug
 

Repositorio Institucional de la Universidad de Granada >
2.-Revistas >
Actualidad Médica >
Actualidad Médica 2011 >
Actual Med 783 >

Please use this identifier to cite or link to this item: http://hdl.handle.net/10481/36431

Title: Evaluación de una prueba rápida para la identificación de Mycobacterium tuberculosis y otras seis especies de micobacterias atípicas directamente desde esputo
Other Titles: Evaluation of a rapid test for the identification of Mycobacterium tuberculosis and six other species of atypical mycobacteria directly from sputum
Authors: Villegas, Enrique
Carrillo, José A.
Sorlózano, Antonio
Román, Juan
Gutiérrez, José
Issue Date: Aug-2011
Abstract: Introducción: El diagnóstico de tuberculosis y, en general, de la patología infecciosa causada por micobacterias, es un proceso lento, que retrasa considerablemente el inicio de un tratamiento antibiótico adecuado. El desarrollo de técnicas moleculares que permitan la detección e identificación de micobacterias directamente en la muestra clínica sería un procedimiento deseable para acortar este periodo. Material y métodos: Se usaron siete cepas de referencia internacional de micobacterias para inocular, de forma artificial, esputos, y realizar pruebas que determinasen la capacidad del ensayo Speed-Oligo Micobacteria® para identificar dichas bacterias directamente, sin necesidad de sembrar las muestras en los medios de cultivo convencionales. Resultados: El ensayo identificó correctamente las siete cepas utilizadas, incluso cuando las bacterias se encontraron en concentraciones inferiores a los límites de detección de la baciloscopia. Conclusiones: El ensayo Speed-Oligo Mycobacteria® podría ser válido para la detección e identificación directa de micobacterias en esputos, incluso en aquellos que presentan una baciloscopia negativa.
Introduction: The diagnosis of tuberculosis and, in general, infectious disease caused by mycobacteria is a slow process, which significantly delayed the initiation of appropriate antibiotic therapy. The development of molecular techniques that allow detection and identification of mycobacteria directly from clinical specimen would be a desirable to shorten this period. Material and methods: We used seven international reference strains of mycobacteria to inoculate, artificially, sputum, and perform tests that determine the ability of the Oligo Speed Mycobacteria® to identify the bacteria directly, without having to grow the samples in conventional culture media. Results: The test correctly identified seven strains used, even when the bacteria were found at concentrations below the detection limits of the smear. Conclusions: The Speed-Oligo Mycobacteria® could be valid for the direct detection and identification of mycobacteria in sputum, including those with a negative smear
Publisher: Real Academia de Medicina y Cirugía de Andalucía Oriental; Universidad de Granada
Keywords: Mycobacterium tuberculosis
Micobacterias no tuberculosas
Speed-Oligo Micobacteria
Non-tuberculous mycobacteria
URI: http://hdl.handle.net/10481/36431
ISSN: 0365-7965
Rights : Creative Commons Attribution-NonCommercial-NoDerivs 3.0 License
Citation: Villegas, E.; et al. Evaluación de una prueba rápida para la identificación de Mycobacterium tuberculosis y otras seis especies de micobacterias atípicas directamente desde esputo. Actualidad Médica, 96(783): 6-11. (2011). [http://hdl.handle.net/10481/36431]
Appears in Collections:Actual Med 783

Files in This Item:

File Description SizeFormat
783_6.pdf121.53 kBAdobe PDFView/Open
Recommend this item

This item is licensed under a Creative Commons License
Creative Commons

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Valid XHTML 1.0! OpenAire compliant DSpace Software Copyright © 2002-2007 MIT and Hewlett-Packard - Feedback

© Universidad de Granada